Contract opportunity

N045--Boiler 3 Oxygen Analyzer and Steam Flow Meter

Combined Synopsis/Solicitation from Department of Veterans Affairs.

Data as of Oct 24, 2026. Sources: SAM.gov and Grants.gov. Snapshot govcon-directory-20261024T104923Z-2151694.

This product uses the Grants.gov API but is not endorsed or certified by the U.S. Department of Health and Human Services. Counts and totals are computed by DSE from public SAM.gov and Grants.gov notices. Text from Grants.gov may be shortened or have contact details removed. The original notice on Grants.gov is the authoritative version.

Closing in 2 days

Notice details

Agency
Department of Veterans Affairs
Sub-tier agency
VETERANS AFFAIRS, DEPARTMENT OF
Notice type
Combined Synopsis/Solicitation
Solicitation number
36C24727Q0050
NAICS
238220 Plumbing, Heating, and Air-Conditioning Contractors
Product/service code
N045
Set-aside
Service-Disabled Veteran-Owned Small Business
Place of performance
Dublin, Georgia
Posted
Oct 23, 2026
Response deadline
Oct 26, 2026
Source
SAM.gov

Description

Questions and Answers 36C24727Q0050 Boiler #3 Oxygen Analyzer and Steam Flow Meter RFI Responses Where should the output signals from the new steam flow meter and O2 analyzer terminate? For example, the existing building automation system (BAS), the existing Boiler 3 burner/boiler controls, or a local display only. Burner 3 boiler/burner controls where applicable and local display. Does the government require active O2 trim control to the burner fuel/air ratio, or monitoring and display of the O2 only? Oxygen analyzer must send signals/information to combustion controls to control trim. What is the material of construction for the stack? Is it single or double wall? Stack is double walled. Inside material is steel; outside material is galvanized steel. Stack is 36 D Selkirk Metalbestos Model P.S. Current operating pressure and temperature of the system for boiler #3? Design pressure is 200 psi. Typical operating pressure is 82 psi. Typical operating temperature is about 330 degrees Fahrenheit. What are the available outputs on the physical steam flow meter (e.g., 4-20 mA, Modbus RTU, BACnet MS/TP)? 4-20 mA analog. Is the flow meter wired directly into an analog terminal block on the CB Hawk, or is it wired directly to the facility s Building Automation System (BMS)? Steam flow meter is wired into local CB Hawk analog terminal block. Please provide nameplates for the existing oxygen analyzer and steam flow meter. Oxygen analyzer nameplate: Steam flow meter nameplate:

Summarized from the official notice.

Official notice

View on SAM.gov →

Requirements and amendments are controlled by the official notice.

DSE verdict

The DSE fit verdict for this notice is available to DSE GovCon subscribers. It is not published on this page.

See DSE GovCon plans →

Similar open notices

  1. Repair Sanitary Waste Piping at the Mann-Grandstaff VA Medical CenterClosing in 2 daysVETERANS AFFAIRS, DEPARTMENT OF · Service-Disabled Veteran-Owned Small Business · Posted Oct 17, 2026 · Closes Oct 26, 2026
  2. Z1ND--EL PASO LIFT STATION PIPING REPAIRClosing in 3 daysVETERANS AFFAIRS, DEPARTMENT OF · Service-Disabled Veteran-Owned Small Business · Posted Oct 24, 2026 · Closes Oct 27, 2026
  3. Z1DA--NRM CONST - 528A7-18-707 - Replace Boiler Stack Rome CBOCClosing in 4 daysVETERANS AFFAIRS, DEPARTMENT OF · Total Small Business · Posted Oct 15, 2026 · Closes Oct 28, 2026
  4. J041--Supply - Upgrade Chiller 3 Controls - NWIClosing in 4 daysVETERANS AFFAIRS, DEPARTMENT OF · Posted Oct 22, 2026 · Closes Oct 28, 2026
  5. J041--Trane BAS HVAC Control System Inspection, Maintenance, Upgrades, and RepairClosing in 4 daysVETERANS AFFAIRS, DEPARTMENT OF · Posted Oct 17, 2026 · Closes Oct 28, 2026

Get free alerts

Email alerts for notices like this one are free on DSE GovCon Intelligence.

Set up free alerts →

Frequently asked questions

When is the response deadline?

The published deadline is Oct 26, 2026. That is 2 days after the data date.

Is there a set-aside?

The notice lists the set-aside Service-Disabled Veteran-Owned Small Business.

What NAICS code applies?

NAICS 238220, Plumbing, Heating, and Air-Conditioning Contractors.

Which agency issued this notice?

Department of Veterans Affairs.

Where is the official notice?

The link under Official notice opens the source listing.