Sewage Ejector and Line Assessment
Solicitation from Department of Defense.
Data as of Oct 24, 2026. Sources: SAM.gov and Grants.gov. Snapshot govcon-directory-20261024T104923Z-2151694.
This product uses the Grants.gov API but is not endorsed or certified by the U.S. Department of Health and Human Services. Counts and totals are computed by DSE from public SAM.gov and Grants.gov notices. Text from Grants.gov may be shortened or have contact details removed. The original notice on Grants.gov is the authoritative version.
Closing in 4 days
Notice details
- Agency
- Department of Defense
- Sub-tier agency
- DEPT OF THE ARMY
- Notice type
- Solicitation
- Solicitation number
- W912BV26QA069
- Product/service code
- J045
- Posted
- Sep 29, 2026
- Response deadline
- Oct 28, 2026
- Source
- SAM.gov
Description
This scope of work requires the contractor to locate, inspect, and modify an unmapped 700 to 800 foot concrete-encased four inch cast iron sewer line and its associated distribution box, with mandatory Government presence during all site inspections. Key tasks include installing concrete-encased Schedule 40 PVC double-Y clean-outs every 300 feet, exposing and inspecting the distribution box and its 2009 leach field connections, and extending the box cover using a riser and structural cover rated for three ton vehicle traffic protected by four concrete-encased steel safety-yellow bollards. All physical, material, and dimensional adjustments must be documented as Red Line As-Builts on the reference drawing, and any recommended corrective actions for the lateral lines must be delivered via a detailed findings report with comprehensive labor and material cost estimates.
Summarized from the official notice.
Official notice
Requirements and amendments are controlled by the official notice.
DSE verdict
The DSE fit verdict for this notice is available to DSE GovCon subscribers. It is not published on this page.
See DSE GovCon plans →Similar open notices
- Repair Building 330 Mod 1 and 3 Underground Plumbing BreakClosing in 3 days
- C 219 Detroit Lead Service Line RemovalClosing in 4 days
- Atchison Storm Sewer Separation Improvements, Atchison, KansasClosing in 20 days
- USACE SPK DBB Construction - Calaveras Wastewater Treatment Plant Improvements - Copperopolis, CAClosing in 44 days
- BRINE PIPELINE ACCESS IMPROVEMENTSClosing in 103 days
Get free alerts
Email alerts for notices like this one are free on DSE GovCon Intelligence.
Set up free alerts →Frequently asked questions
When is the response deadline?
The published deadline is Oct 28, 2026. That is 4 days after the data date.
What NAICS code applies?
NAICS 237110, Water and Sewer Line and Related Structures Construction.
Which agency issued this notice?
Department of Defense.
Where is the official notice?
The link under Official notice opens the source listing.